Week 41: October 5 - 12 Last updated:   08-Oct-20 16:05
Maintenance this week Date Time & Length Production resumes
520 MeV Tuesday, Oct. 6 6 hr maintenance starting at 08:30 - 14:30, followed by 3 hours start-up & tuning 17:30
ISIS will be tuned by Experts during maintenance.
ISAC Tuesday, Oct. 6 8 hr followed by 16 hr of start-up
E-LINAC Maintenance on-going. E-Hall open Monday - Wednesday until portable power station installed.
                   
GROUP ACTIVITY Fault Report Work Permit
ATG TBD @ STF  (continue tgt failure investigations 520 MeV - C2020-10-06-10 ongoing
Beamlines Address 1AQ6 water flow fault (lower vault controlled access) 520 MeV 13472 C2020-10-06-1 y
Troubleshoot 1VB1 (water flow, lower vault controlled access) 520 MeV 13418 C2020-10-06-1 y
Computing and Networking
Controls  GEC1-b6-c01 troubleshooting and fault correction 520 MeV 13475 C2020-10-06-6 y
Cryogenics and Vacuum Replace 1TP2.5 controller 520 MeV 13399 C2020-10-06-2 y
Check oil level in pumps and add oil to blower #3  520 MeV - C2020-10-06-7 y
ISAC Target Hall ITW -> ITE ISAC - - y
ISIS Tune ISIS for higher currents 520 MeV - - y
Regenerate cryopumps if necessary  520 MeV - C2020-10-06-3 y - more work needed
Magnets and Power Supplies Troubleshoot 1VB1 ps instability  520 MeV 13469 C2020-10-06-4 y
Operations Switch from 2A2/ITW -> 2A3/ITE 520 MeV/ISAC - - y
Sump checks All - - y
SCBCD & SCRM Tests 520 MeV - - y
Remote Handling
RF Increase cyclotron RF DV 520 MeV - - y
Safety
Site Services SAB3 pump check 520 MeV - - n
Mechanical, Civil/Structural, Electrical, FAS ISAC Cooling Tower preventative maintenance ISAC - y
E-LINAC HAW work in SAB3 Tunnel E-Hall - y